premultiply created a comment on a pull request on evcc-io/evcc
"hold" means disable discharge of the battery. If that is not possible battery should be disabled completly. Whenever possible do not use any SoC or time related controls for battery control.
premultiply created a comment on an issue on evcc-io/evcc
Das ist derzeit nicht möglich. Es gibt bislang nur die Ext-Meters, die aber nicht in der UI angezeigt werden.
premultiply closed an issue on evcc-io/evcc
Heidelberg Amperfied Wallbox OCPP: Lademodus wechseln nicht möglich
### Describe the bug Vor zwei Wochen hatte ich bereits ein Ticket eröffnet. Dort hat sich herausgestellt das die Wallbox kein Smart Charging unterstützt: https://github.com/evcc-io/evcc/issues/1...premultiply created a comment on an issue on evcc-io/evcc
> ``` > - name: battery_1 > type: template > template: huawei-sun2000 > id: 1 > host: 192.168.178.149 > port: 502 > usage: battery > modbus: tcpip > timeo...
premultiply closed an issue on evcc-io/evcc
Meter: Huawei SUN2000 - Second battery is not measured - Only battery_1
### Describe the bug Connection to inverter via modbus tcpip: - Connect to inverter's internal WLAN (NOT to SDongle) - Connect via modbusProxy Setup: ``` # # Huawei SUN2000-6KTL-M1 (...premultiply closed an issue on evcc-io/evcc
MinPV not triggering the charge end
### Describe the bug In the `minpv` (/api/loadpoints/1/mode/minpv) configuration, the charging session will not stop if the threshold of the `pv charge current` is below the `min. current` (see ...premultiply created a comment on an issue on evcc-io/evcc
Thank you. Could you please try if the error is the same for ``` evcc meter --battery-mode normal --log trace,db:error -c /etc/evcc.yaml ``` and ``` evcc meter --battery-mode charge --log t...
premultiply created a comment on a pull request on evcc-io/evcc
Our current implementation level of SG Ready recommendation interface does only support the boost case. It is a kind of first step. There are several aspects that may be improved and for sure we...
premultiply created a comment on an issue on evcc-io/evcc
Vehices could be (re)assigned manually at any time. You do not need to restart anything. Just use the UI (or API) to fix a situation where the vehicle detection is not possible.
premultiply created a comment on an issue on evcc-io/evcc
Out of scope here but maybe add a "kiosk mode" view (option) at the same that limits the view to a single specified loadpoint?
premultiply created a comment on a pull request on evcc-io/evcc
I wonder how MQTT should make synchronous communication possible in this way, since to my knowledge any client can write in any order at any time on a topic. There is missing a message ID to track ...
premultiply created a comment on an issue on evcc-io/evcc
> [main ] INFO 2025/01/06 16:17:23 using config file: /home/kjohann/evcc.yaml > [db ] INFO 2025/01/06 16:17:23 using sqlite database: /home/kjohann/.evcc/evcc.db Hier wird eine andere Konfigdat...
premultiply created a comment on an issue on evcc-io/evcc
Right. The heatpump should shut off on its own when the target temperature is reached. Exactly like a BMS would stop charging if the battery reached the target of 100% state of charge. SG Ready...
premultiply created a comment on a pull request on evcc-io/evcc
> I only have correct values from the additional smart meter that can be connected to the inverter. This is exactly what is needed for grid meter.
premultiply created a comment on an issue on evcc-io/evcc
This is correct, but exactly this does not require knowledge and control over temperatures.
premultiply created a comment on an issue on evcc-io/evcc
Mmmh. This should be better solved via a thermostat or home automation? The task of evcc is energy management. To this end, it _permits_ or _prohibits_ individual consumers to obtain electrical ...
premultiply closed an issue on evcc-io/evcc
Geladene kWh für Ladevorgang falsch ausgewertet
### Describe the bug Obwohl Zählerstände zu Beginn und Ende des Ladevorgangs richtig erkannt wurden, hat evcc falsch gerechnet. Der Wert für die geladene Energiemenge wird uns nicht nachvollziehb...premultiply created a comment on an issue on evcc-io/evcc
Das Problem lässt sich normalerweise gut über ein LM-Circuit entschärfen. Limit des Circuits der Box auf 11 kW und auf 20A setzen. Die Box muss natürlich dann dauerhaft auf den höchsten Phasenstr...
premultiply created a comment on an issue on evcc-io/evcc
Bei 0x40A0 passt keine der Beschreibungen in diversen Dokumenten von SAJ. Da geht es nur um Loads (Hausverbrauch). Von der Beschreibung her ergibt nur `0x40A7` oder vielleicht noch `0x40AD` größer...
premultiply closed a pull request on evcc-io/evcc
Enphase Envoy: add currents
Added support phase currents, and three-phase with Enphase envoy #16744premultiply created a review comment on a pull request on evcc-io/evcc
```suggestion insecure: true ```
premultiply pushed 1 commit to master evcc-io/evcc
- Translations update from Hosted Weblate (#17958) * Translated using Weblate (Bulgarian) Currently translated at 92.... b7a843d